Tratos supply a wide range cables suitable for applications where resistance to extreme temperatures are required. Our Silicone range of cables are able to withstand temperatures ranging from -60°C up to +180°C.

TRATOS RS HT (EF)

HIGH TEMPERATURE POWER CABLES

3,6/6 kV – single core with extra flexible conductor. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits, inter coaches power circuits.

Construction

Conductor

extra flexible tinned annealed copper wires

(plain copper only for 150° C core temperature)

class 6 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 111)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-HT

HIGH TEMPERATURE POWER CABLES

1,8/3 or 3,6/6 kV – sheathed single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits.

Construction

Conductor

flexible tinned annealed copper wires

(plain copper only for 150° C core temperature)

class 5 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 112)

Outer sheath

LSZH elastomeric compound according to EN 50382-1

(EM 105, EM 106 or EM 107)

Black (other colours if required)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-HT

HIGH TEMPERATURE POWER CABLES

1,8/3 or 3,6/6 kV – single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits.

Construction

Conductor

flexible tinned annealed copper wires

(palin copper only for 150° C core temperature)

class 5 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 111)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-MW

MEDIUM WALL POWER AND CONTROL CABLES

0,6/1 kV – screened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Overal screen

tinned annealed copper wires with required diameter

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-MW

MEDIUM WALL POWER AND CONTROL CABLES

1,8/3 or 3,6/6 kV – sheathed single core with reduced dimensions. Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

screen (only for 3,6/6 kV) conductive tape or extruded conductive layer

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 106 to EI 109)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 3 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-MW

MEDIUM WALL POWER AND CONTROL CABLES

0,6/1 or 1,8/3 kV – unscreened insulated single core with reduced dimensions. Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Standards

EN 50264 – 3 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS SS-SW

STANDARD WALL POWER AND CONTROL CABLES

300/500 V or 0,6/1 kV – screened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Overal screen

tinned annealed copper wires with required diameter

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 2

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-SW

STANDARD WALL POWER AND CONTROL CABLES

300/500 V or 0,6/1 kV – unscreened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, lighting circuits, auxiliary and electric heating circuits, control and monitoring circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 2

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-SW

STANDARD WALL POWER AND CONTROL CABLES

1,8/3 or 3,6/6 kV – sheathed single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-SW

STANDARD WALL POWER AND CONTROL CABLES

0,6/1 or 1,8/3 kV – unscreened insulated single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS® DOUBLE INSULATED FEP

FEP CABLES 300/500 V

For use in wiring class 2 appliances, where exposed to hot or cold environments or aggressive chemicals.

Construction

Conductor: Flexible tinned copper

First insulation: Fluorinated polymer FEP

Second insulation: Fluorinated polymer FEP

Standards

VDE 0250

ELECTRICAL CHARACTERISTICS

Voltage rating: 300/500 V

Temperature range: -90 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® FEP (F6Y)

FEP CABLES 300/500 V

For use in lighting, automotive, electrical appliances, electronics and medical equipment.

Construction

Conductor: Flexible tinned copper

Insulation: Fluorinated polymer FEP

Standards

VDE 0250

ELECTRICAL CHARACTERISTICS

Voltage rating: 300/500 V

Temperature range: -100 ºC to +180 ºC

Test voltage: 2500 V

TRATOS® SIFL/PVC/VDE

SILICONE CABLES 500 V

For use in lighting, electrical appliances, furnaces, medical equipment and electro mechanics.

Construction

Conductor: Flexible tinned copper (Conductor available in plain or nickel plated copper)

Insulation: Silicone rubber

Sheath: PVC

Standards

CE VDE

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -30 ºC to +90 ºC

Test voltage: 2000 V

TRATOS® SIFL/PVC

SILICONE CABLES 500 V

For use in lighting, electrical appliances, furnaces, medical equipment and electro mechanics.

Construction

Conductor: Flexible tinned copper (Conductor available in plain or nickel plated copper)

Insulation: Silicone rubber

Sheath: PVC

Standards

CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -30 ºC to +90 ºC

Test voltage: 2000 V

TRATOS® SIFL

SILICONE CABLES 500 V

Internal wiring of appliances and lighting equipment where they are enclosed and protected against mechanical abuse.

Construction

Conductor: Flexible tinned copper (Conductor available in plain or nickel plated copper)

Insulation: Silicone rubber

Sheath: Silicone

Standards

CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® EN 50143-D2

SILICONE CABLES 10 kV

Internal wiring of ignition equipment, electrical sign and high voltage neon sign installations.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Braid: Copper screen

Outer sheath: Halogen free compound

Standards

EN 50143-D2

ELECTRICAL CHARACTERISTICS

Voltage rating: 10 kV

Temperature range: -20 ºC to +90 ºC

Test voltage: 15 kV

TRATOS® EN 50143-D1

SILICONE CABLES 10 kV

Internal wiring of ignition equipment, electrical sign and high voltage neon sign installations.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Braid: Copper screen

Outer sheath: PVC

Standards

EN 50143-D1

ELECTRICAL CHARACTERISTICS

Voltage rating: 10 kV

Temperature range: -20 ºC to +90 ºC

Test voltage: 15 kV

TRATOS® EN 50143-C2

SILICONE CABLES 10 kV

Internal wiring of ignition equipment, electrical sign and high voltage neon sign installations.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Outer sheath: Halogen free compound

Standards

EN 50143-C2

ELECTRICAL CHARACTERISTICS

Voltage rating: 10 kV

Temperature range: -20 ºC to +90 ºC

Test voltage: 15 kV

TRATOS® EN 50143-C1

SILICONE CABLES 10 kV

Internal wiring of ignition equipment, electrical sign and high voltage neon sign installations.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Outer sheath: PVC

Standards

EN 50143-C1

ELECTRICAL CHARACTERISTICS

Voltage rating: 10 kV

Temperature range: -20 ºC to +90 ºC

Test voltage: 15 kV

TRATOS® EN 50143-B

SILICONE CABLES 10 kV

Internal wiring of ignition equipment, electrical sign and high voltage neon sign installations.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Standards

EN 50143-B

ELECTRICAL CHARACTERISTICS

Voltage rating: 10 kV

Temperature range: -60 ºC to +180 ºC

Test voltage: 15 kV

TRATOS® H05SS-K

SILICONE CABLES 300/500 V

Recommended for wiring class 2 appliances where the cable must be non-flammable.

Construction

Conductor: Flexible  tinned  copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Sheath: Silicone rubber

Standards

IMQ CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 300/500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 5 kV

TRATOS® H05SJ-K

SILICONE CABLES 300/500 V

Internal wiring of appliances, lighting, power supplies and electronics where no mechanical protection is required.

Construction

Conductor: Flexible  tinned  copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Braid: Fibreglass

Standards

IMQ CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 300/500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® H05SS-F

SILICONE CABLES 500 V

For internal wiring of appliances and lighting equipment where they are enclosed and protected against mechanical abuse.

Construction

Conductor: Flexible tinned copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Sheath: Silicone rubber

Standards

HD 22.15.S1

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® H05S-U

SILICONE CABLES 500 V

Good resistance to heat and cold, this cable is recommended for use in demanding thermal conditions.

Construction

Conductor: Solid  tinned  copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Standards

IMQ CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® H05S-K

SILICONE CABLES 500 V

Good resistance to heat and cold, this cable is recommended for use in demanding thermal conditions.

Construction

Conductor: Flexible  tinned  copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Standards

IMQ CE

ELECTRICAL CHARACTERISTICS

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® SIA/GL

SILICONE CABLES 500 V

Internal wiring of appliances, lighting, power supplies and electronics where no mechanical protection is required.

Construction

Conductor: Solid tinned copper (Conductor also available in plain or nickel plated copper)

Insulation: Silicone rubber

Braid: Fibreglass

Standards

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® SIAF/GL

SILICONE CABLES 500 V

Internal wiring of appliances, lighting, power supplies and electronics where no mechanical protection is required.

Construction

Conductor: Flexible tinned copper (Conductor also available in plain or nickel plated copper)

Insulation: Silicone rubber

Braid: Fibreglass

Standards

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® SIHF

SILICONE CABLES 300/500 V

For use in lighting, electrical appliances, ovens and electro mechanics under light mechanical stress.

Construction

Conductor: Flexible tinned copper

Insulation: Silicone rubber

Sheath: Silicone rubber

Standards

Voltage rating: 300/500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® SIAF

SILICONE CABLES 500 V

Internal wiring of appliances, lighting, power supplies and electronics where no mechanical protection is required.

Construction

Conductor: Flexible tinned copper (Also available in plain or nickel plated conductors)

Insulation: Silicone rubber

Standards

Voltage rating: 500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

TRATOS® SIA

SILICONE CABLES 300/500 V

Internal wiring of appliances, lighting, power supplies and electronics where no mechanical protection is required.

Construction

Conductor: Solid tinned copper

Insulation: Silicone rubber

Standards

Voltage rating: 300/500 V

Temperature range: -60 ºC to +180 ºC

Test voltage: 2000 V

Cables

TRATOS RS HT (EF)

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits, inter coaches power circuits

TRATOS RS US-HT

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits

TRATOS RS UU-HT

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits

TRATOS RS US-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits

TRATOS RS US-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits

TRATOS RS UU-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits