Tratos has been producing cables for use in the Oil & Gas industry for over 50 years. We provide cables for a large variety of onshore and offshore operations, including umbilical cables for offshore applications, which have been supplied in conjunction with our partner MFX, as well as highly specialised submarine cables.

TRATOS-ACS-FR-SW2-F0 - TRATOS-ACS-FR-SW4-F0

INSTRUMENTATION CABLES ACCORDING TO BS7917

TRATOS-ACS-FR-SW2-F0 (or F1) – Armoured Collectively Screened Reduced Halogen Fire Resistant, TRATOS-ACS-FR-SW4-F0 (or F1) – Armoured Collectively Screened Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: mica tape + EPR

Lay-up: pairs, triples or quads

Assembly: multipairs, triples or quads laid up

Collective screen: overall aluminium/polyester tape + tinned
copper drain wire

Inner sheath: thermosetting elastomeric compound

Armour: galavanised steel wire braid (tinned copper on request)

Sheath: SW2 reduced halogen

SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-ACS-FR-SW2-FO 3x2x1 (I) 150/250V BS 7917 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60331-11 and IEC 60331-21  Fire resistance (limited circuit integrity)

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-AIS-FR-SW2-F0 - TRATOS-AIS-FR-SW4-F0

INSTRUMENTATION CABLES ACCORDING TO BS7917

TRATOS-AIS-FR-SW2-F0 (or F1) – Armoured Individually Screened Reduced Halogen Fire Resistant, TRATOS-AIS-FR-SW4-F0 (or F1) – Armoured Individually Screened Halogen Free Fire Resistant

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: mica tape + EPR

Lay-up: pairs, triples or quads

Individual screen: aluminium/polyester tape + tinned copper drain wire

Assembly: multipairs, triples or quads laid up

Inner sheath: thermosetting elastomeric compound

Armour: galavanised steel wire braid (tinned copper on request)

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-AIS-FR-SW2-FO 3x2x1 (I) 150/250V BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 7917 Design guide

BS 7655 Materials

IEC 60331-11 and IEC 60331-21  Fire resistance (limited circuit integrity)

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-ACS-SW2 - TRATOS-ACS-SW4

INSTRUMENTATION CABLES ACCORDING TO BS6883

TRATOS-ACS-SW2 – Armoured Collectively Screened Reduced Halogen, TRATOS-ACS-SW4 – Armoured Collectively Screened Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Lay-up: pairs, triples or quads

Assembly: multipairs, triples or quads laid up

Collective screen: overall aluminium/polyester tape + tinned copper drain wire

Inner sheath: thermosetting elastomeric compound

Armour: galavanised steel wire braid (tinned copper on request)

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-ACS-SW2 3x2x1 (I) 150/250V BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-AIS-SW2 - TRATOS-AIS-SW4

INSTRUMENTATION CABLES ACCORDING TO BS6883

TRATOS-AIS-SW2 – Armoured Individually Screened Reduced Halogen, TRATOS-AIS-SW4 – Armoured Individually Screened Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Lay-up: pairs, triples or quads

Individual screen: aluminium/polyester tape + tinned copper drain wire

Assembly: multipairs, triples or quads laid up

Inner sheath: thermosetting elastomeric compound

Armour: galavanised steel wire braid (tinned copper on request)

Sheath: SW2 reduced halogen

SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-AIS-SW2 3x2x1 (I) 150/250V
BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-UCS-SW2 - TRATOS-UCS-SW4

INSTRUMENTATION CABLES ACCORDING TO BS6883

TRATOS-UCS-SW2 – Unarmoured Collectively Screened Reduced Halogen, TRATOS-UCS-SW4 – Unarmoured Collectively Screened Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Lay-up: pairs, triples, quads

Assembly: multipairs, triples or quads laid up

Collective screen: overall  aluminium/polyester tape + tinned copper drain wire

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-UCS-SW2 3x2x1 (C) 15/250 V
BS 6883 + year +  metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-UIS-SW2 - TRATOS-UIS-SW4

INSTRUMENTATION CABLES ACCORDING TO BS6883

TRATOS-UIS-SW2 – Unarmoured Individually Screened Reduced Halogen, TRATOS-UIS-SW4 – Unarmoured Individually Screened Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Lay-up: pairs, triples or quads

Individual screen: aluminium/polyester tape + tinned copper
drain wire

Assembly: multipairs, triples or quads laid up

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: grey or blue

Example of marking: TRATOS-UIS-SW2 3x2x1 (I) 150/250V
BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

IEC 60332-3A Flame retardant

IEC 60754-1; IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

TRATOS-MVA-SW2 - TRATOS-MVA-SW4

MEDIUM VOLTAGE POWER AND CONTROL CABLES ACCORDING TO BS6883

TRATOS-MVA-SW2 – Armoured Reduced Halogen, TRATOS-MVA-SW4 – Armoured Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: semiconductive layer+EPR+ semiconducting layer

Inner sheath: Thermosetting elastomeric compound

Armour: galavanised steel wire braid (tinned phosphor bronze for single core)

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: red

Example of marking: TRATOS-A-SW4 3×120 3,8/6,6 kV BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-A-FR-SW2-F0 - TRATOS-A-FR-SW4-F0

LOW VOLTAGE POWER AND CONTROL CABLES ACCORDING TO BS6883 - BS7917

TRATOS-A-FR-SW2-F0 (or F1 950 °C) – Armoured Reduced Halogen Fire Resistant, TRATOS-A-FR-SW4-F0 (or F1 950 °C) – Armoured Halogen Free  Fire Resistant

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: mica tape + EPR

Inner Sheath: Thermosetting elastomeric compound

Armour: galavanised steel wire (tinned bronze for single core)

Outer Sheath: SW2 reduced halogen
              SW4 halogen free

Standard colour: black

Example of marking: TRATOS-A-FR-SW2 3x 1,5 600/1000V
BS 7917 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-U-FR-SW2-F0 - TRATOS-U-FR-SW4-F0

LOW VOLTAGE POWER AND CONTROL CABLES ACCORDING TO BS7917

TRATOS-U-FR-SW2-F0 (or F1 950 °C) – Unarmoured Reduced Halogen Fire Resistant, TRATOS-U-FR-SW4-F0 (or F1 950 °C)- Unarmoured Halogen Free Fire Resistant

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: mica tape + EPR

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: black

Example of marking: TRATOS-U-FR- SW2 3×1,5 600/1000V
BS 7917 + year + metre marking

* Class 5 conductor when requested

Standards

BS 7917 Design guide

BS 7655 Materials

IEC 60331-11 and IEC 60331-21  Fire resistance (limited circuit integrity)

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-A-SW2 - TRATOS-A-SW4

LOW VOLTAGE POWER AND CONTROL CABLES ACCORDING TO BS6883

TRATOS-A-SW2 – Armoured Reduced Halogen, TRATOS-A-SW4 – Armoured Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Inner Sheath: Thermosetting elastomeric compound

Armour: galavanised steel wire (tinned bronze for single core)

Outer Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: black

Example of marking: TRATOS-A-SW2 3x 1,5 600/1000V
BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

TRATOS-U-SW2 - TRATOS-U-SW4

LOW VOLTAGE POWER AND CONTROL CABLES ACCORDING TO BS6883

TRATOS-U-SW2 – Unarmoured Reduced Halogen – TRATOS-U-SW4 – Unarmoured Halogen Free

Construction

Conductor: tinned copper wire stranded circular cl.2*

Insulation: EPR

Sheath: SW2 reduced halogen
SW4 halogen free

Standard colour: black

Example of marking: TRATOS-U-SW2 3×1,5 600/1000V
BS 6883 + year + metre marking

* Class 5 conductor when requested

Standards

BS 6883 Design guide

BS 7655 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2 Smoke emission

CSA C22.2 No.38-95 (on request)

Cables

(XLPE/CuT/TratosCB®/PVC)

Multi-core, triple extruded insulation, power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present without using Lead

(XLPE/TratosCB®/PVC)

Single core, triple extruded insulation, power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present without using Lead

(XLPE/CuT/Pb/PVC)

Multi-core, triple extruded insulation, lead sheathed power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present

(XLPE/Pb/PVC)

Single core, triple extruded insulation, lead sheathed power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present

(XLPE/CuW/PSA/PE)

Multi-core, triple extruded insulation, non-metallic mechanical protection, sheathed cable for fixed installations for use in Medium Voltage circuits at voltages up to 18/30 (36) kV, in the petroleum industry, chemical and petrochemical plants

(XLPE/CuW/PSA/PE)

Single core, triple extruded insulation, non-metallic mechanical protection, sheathed cable for fixed installations for use in Medium Voltage circuits at voltages up to 18/30 (36) kV, in the petroleum industry, chemical and petrochemical plants

TRATOS® BFOU(c) S4/S8

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant - Common Screen

TRATOS® BFOU(i) S3/S7

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant - Individual Screen

TRATOS® BFOU P5/P12

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant

TRATOS® UX P15

CU/EVA - Halogen Free & MUD Resistant

TRATOS® RFOU P4/P11 - 8.7/15 kV - TRATOS® RFOU P19/P21 - 12/20 kV

CU/EPR/ZERO HAL/TCWB/EVA - Halogen Free & MUD Resistant

TRATOS® RFOU P2/P9 - 3.6/6 kV - TRATOS® RFOU P3/P10 - 6/10 kV

CU/EPR/ZERO HAL/TCWB/EVA - Halogen Free & MUD Resistant

TRATOS-JBA-MVA-FR-SHF2

Armoured Halogen Free - Fire Resistant- Mud Resistant

TRATOS-JBA-MVA-SHF2

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-A-FR-SHF2 - 0,6/1 kV

Armoured Halogen Free - Fire Resistant - Mud Resistant

TRATOS-JBA-A-SHF2 - 0,6/1 kV

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-U-SHF2

Unarmoured Halogen Free - Mud Resistant

TRATOS-ACS-FR-SW2-F0 - TRATOS-ACS-FR-SW4-F0

TRATOS-ACS-FR-SW2-F0 (or F1) - Armoured Collectively Screened Reduced Halogen Fire Resistant, TRATOS-ACS-FR-SW4-F0 (or F1) - Armoured Collectively Screened Halogen Free

TRATOS-AIS-FR-SW2-F0 - TRATOS-AIS-FR-SW4-F0

TRATOS-AIS-FR-SW2-F0 (or F1) - Armoured Individually Screened Reduced Halogen Fire Resistant, TRATOS-AIS-FR-SW4-F0 (or F1) - Armoured Individually Screened Halogen Free Fire Resistant

TRATOS-ACS-SW2 - TRATOS-ACS-SW4

TRATOS-ACS-SW2 - Armoured Collectively Screened Reduced Halogen, TRATOS-ACS-SW4 - Armoured Collectively Screened Halogen Free

TRATOS-AIS-SW2 - TRATOS-AIS-SW4

TRATOS-AIS-SW2 - Armoured Individually Screened Reduced Halogen, TRATOS-AIS-SW4 - Armoured Individually Screened Halogen Free

TRATOS-UCS-SW2 - TRATOS-UCS-SW4

TRATOS-UCS-SW2 - Unarmoured Collectively Screened Reduced Halogen, TRATOS-UCS-SW4 - Unarmoured Collectively Screened Halogen Free

TRATOS-UIS-SW2 - TRATOS-UIS-SW4

TRATOS-UIS-SW2 - Unarmoured Individually Screened Reduced Halogen, TRATOS-UIS-SW4 - Unarmoured Individually Screened Halogen Free