Tratos has been producing cables for use in the oil and gas industry for over 50 years. We provide cables for a large variety of onshore and offshore operations, including umbilical cables for offshore applications, which have been supplied in conjunction with our partner MFX, as well as highly specialised submarine cables.

TRATOS® BFOU(c) S4/S8

INSTRUMENTATION 250 V CABLES ACCORDING TO NEK606

CU/MT/EPR/ZERO HAL/TCWB/EVA – Halogen Free, MUD Resistant & Fire Resistant – Common Screen

Construction

Conductor: Tinned stranded compacted copper IEC 60228 class 2

Insulation: mica tape + halogen free EPR compound

Assembled pairs/triples

Common screen: copper/polyester tape tinned copper drain wire

Bedding: halogen free compound

Armour: tinned copper wire braid according to IEC 60092-376:2003

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: grey (blue for intrinsically safe)

Standards

Design and construction: IEC 60092-353

Nominal Voltage: 250 V

Operating temperature: 90°C

IEC 60332-1 IEC 60332-3-22 Flame retardancy

IEC 60331-31 Fire resistant

IEC 60754-1 IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

NEK 606:2009  IEC 61892 Annex D MUD resistance

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

TRATOS® BFOU(i) S3/S7

INSTRUMENTATION CABLES 250 V ACCORDING TO NEK606

CU/MT/EPR/ZERO HAL/TCWB/EVA – Halogen Free, MUD Resistant & Fire Resistant – Individual Screen

Construction

Conductor: Tinned stranded copper IEC 60228 class 2

Insulation: mica tape + halogen free EPR compound

Pairs/triples: numbered and individually screened by copper/polyester tape + tinned copper drain wire

Bedding: halogen free compound

Armour: Tinned copper wire braid according to IEC 60092-376:2004

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: grey or blue for intrinsically safe (other colours available on request)

Standards

Design and construction: IEC 60092-353

Nominal Voltage: 250 V

Operating temperature: 90°C

IEC 60332-1 IEC 60332-3-22 Flame retardancy

IEC 60331-31 Fire resistant

IEC 60754-1 IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

NEK 606:2009 IEC 61892-4 Annex D MUD resistance

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

TRATOS® BFOU P5/P12

POWER AND CONTROL CABLES 0.6/1 kV ACCORDING TO NEK606

CU/MT/EPR/ZERO HAL/TCWB/EVA – Halogen Free, MUD Resistant & Fire Resistant

Construction

Conductor: Tinned copper IEC 60228 class 2*

Insulation: mica tape + halogen free EPR compound

Separator (if necessary): halogen free tape

Bedding: halogen free compound

Armour: tinned copper wire braid according to IEC 60092-352

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: black (other colours available on request)

* Flexible construction when requested

Standards

Design and construction: IEC 60092-353

Nominal Voltage: 0.6/1 kV

Operating temperature: 90°C

IEC 60332-1 IEC 60332-3-22 Flame retardancy

IEC 60331-31 Fire resistant

IEC 60754-1 IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

NEK 606:2009 & IEC 61892-4 Annex D MUD resistance

CSA C22.2 No 38-95 Cold bend and impact test (-40ºC) (on request)

TRATOS® UX P15

EARTHING CABLES 1000 V ACCORDING TO IEC 60092-354

CU/EVA – Halogen Free & MUD Resistant

Construction

Conductor: tinned copper IEC 60228 Class 2

Insulation: SHF2 thermoset compound halogen free & MUD resistant

Standards

Design and Construction: IEC 60092-354

Flame retardancy: IEC 60332-1    

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke density: IEC 61034-1-2

MUD resistance: NEK 606:2009; IEC 61892-4 Annex D

on request: Cold bend and Impact test (-40 Deg C) CSA C22.2 No 38-95

TRATOS® RFOU P4/P11 - 8.7/15 kV - TRATOS® RFOU P19/P21 - 12/20 kV

MEDIUM VOLTAGE CABLES ACCORDING TO NEK606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant

Construction

Conductor: tinned copper IEC 60228 class 2*

Conductor screen: semiconducting layer

Insulation: halogen free HEPR compound

Insulation screen: semiconducting layer

Screen: tinned copper wire braid according to IEC 60092-352

Bedding: halogen free compound

Armour: tinned copper wire braid

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: red (other colours available on request)

* Flexible construction when requested

Standards

Design and Construction: IEC 60092-354; IEC 60502

Nominal Voltage: 8.7/15 kV – 12/20 kV

Maximum Rated Temperature: 90º C

Flame Retardancy: IEC 60332-1; IEC 60332-3-22**

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke Density: IEC 61034-2

MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

** Fire resistant upon request

TRATOS® RFOU P2/P9 - 3.6/6 kV - TRATOS® RFOU P3/P10 - 6/10 kV

MEDIUM VOLTAGE CABLES ACCORDING TO NEK606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant

Construction

Conductor: tinned copper IEC 60228 class 2*

Conductor screen: semiconducting layer

Insulation: halogen free HEPR compound

Insulation screen: semiconducting layer

Screen: tinned copper wire braid according to IEC 60092-352

Bedding: halogen free compound

Armour: tinned copper wire braid

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: red (other colours available on request)

* Flexible construction when requested

Standards

Design and Construction: IEC 60092-354; IEC 60502

Nominal Voltage: 3.6/6 kV 6/10 kV

Maximal Rated Temperature: 90º C

Flame Retardancy: IEC 60332-1; IEC 60332-3-22**

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke Density: IEC 61034-2

MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

** Fire resistant upon request

TRATOS® RFOU(c) S2/S6

INSTRUMENTATION CABLES 250 V ACCORDING TO NEK606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant – Common screen

Construction

Conductor: tinned stranded copper wire IEC 60228 class 2

Insulation: halogen free EPR compound

Assembled pairs/triples

Common screen: by copper/polyester tape + stranded tinned copper tinned drain wire

Bedding: halogen free compound

Armour: tinned copper wire braid according to IEC 60092-376:2003

Outer sheath: SHF2 thermoset compound Halogen free & MUD resistant

Sheath colour: grey (blue for intrinsically safe and others available on request)

Standards

Design and Construction: IEC 60092-376

Nominal Voltage: 250 V

Operating Temperature: 90º C

Flame Retardancy: IEC 60332-1; IEC 60332-3-22

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke Density: IEC 61034-2

MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

TRATOS® RFOU(i) S1/S5

INSTRUMENTATION CABLES 250 V ACCORDING TO NEK606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant – Individual screen

Construction

Conductor: stranded tinned copper IEC 60228 Class 2

Insulation: halogen free EPR compound

Pairs/triples: numbered and individually screened by copper/polyester tape + stranded tinned copper drain wire

Bedding: halogen free compound

Armour: tinned copper wire braid according to IEC 60092-376:2003

Outer sheath: SHF2 thermoset compound halogen free & MUD resistant

Sheath colour: grey (blue for intrinsically safe)

Standards

Design and construction: IEC 60092-353

Nominal Voltage: 250 V

Operating temperature: 90°C

Flame Retardancy: IEC 60332-1 IEC 60332-3-22

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke Density: IEC 61034-2

MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D

CSA C22.2 No 38-95 Cold bend and Impact test (-40ºC) (on request)

TRATOS® RFOU P1/P8

POWER AND CONTROL CABLES 0.6/1 kV ACCORDING TO NEK606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant

Construction

Conductor: tinned copper IEC 60228 Class 2*

Insulation: halogen free EPR compound

Bedding: halogen free compound

Armour: Tinned copper wire braid

Outer sheath: SHF2 thermoset compound halogen free & MUD resistance

Sheath colour: black, other colours on request

* Flexible construction when requested

Standards

Design and construction: IEC 60092-353

Nominal Voltage  Uo/U: 0.6/1 kV

Operating temperature: 90°C

Flame retardancy: IEC 60332-1; IEC 60332-3-22

Corrosivity: IEC 60754-1; IEC 60754-2

Smoke density: IEC 61034-2

MUD resistance: NEK 606:2009; IEC 61892-4 Annex D

On request: Cold bend and Impact test (-40°C) CSA C22.2 No 38-9

Cables

(XLPE/CuT/TratosCB®/PVC)

Multi-core, triple extruded insulation, power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present without using Lead

(XLPE/TratosCB®/PVC)

Single core, triple extruded insulation, power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present without using Lead

(XLPE/CuT/Pb/PVC)

Multi-core, triple extruded insulation, lead sheathed power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present

(XLPE/Pb/PVC)

Single core, triple extruded insulation, lead sheathed power cable for indoor and outdoor installations in the petroleum industry, chemical and petrochemical plant in and around process plants where hydrocarbons are present

(XLPE/CuW/PSA/PE)

Multi-core, triple extruded insulation, non-metallic mechanical protection, sheathed cable for fixed installations for use in Medium Voltage circuits at voltages up to 18/30 (36) kV, in the petroleum industry, chemical and petrochemical plants

(XLPE/CuW/PSA/PE)

Single core, triple extruded insulation, non-metallic mechanical protection, sheathed cable for fixed installations for use in Medium Voltage circuits at voltages up to 18/30 (36) kV, in the petroleum industry, chemical and petrochemical plants

TRATOS® BFOU(c) S4/S8

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant - Common Screen

TRATOS® BFOU(i) S3/S7

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant - Individual Screen

TRATOS® BFOU P5/P12

CU/MT/EPR/ZERO HAL/TCWB/EVA - Halogen Free, MUD Resistant & Fire Resistant

TRATOS® UX P15

CU/EVA - Halogen Free & MUD Resistant

TRATOS® RFOU P4/P11 - 8.7/15 kV - TRATOS® RFOU P19/P21 - 12/20 kV

CU/EPR/ZERO HAL/TCWB/EVA - Halogen Free & MUD Resistant

TRATOS® RFOU P2/P9 - 3.6/6 kV - TRATOS® RFOU P3/P10 - 6/10 kV

CU/EPR/ZERO HAL/TCWB/EVA - Halogen Free & MUD Resistant

TRATOS-JBA-MVA-FR-SHF2

Armoured Halogen Free - Fire Resistant- Mud Resistant

TRATOS-JBA-MVA-SHF2

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-A-FR-SHF2 - 0,6/1 kV

Armoured Halogen Free - Fire Resistant - Mud Resistant

TRATOS-JBA-A-SHF2 - 0,6/1 kV

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-U-SHF2

Unarmoured Halogen Free - Mud Resistant

TRATOS-ACS-FR-SW2-F0 - TRATOS-ACS-FR-SW4-F0

TRATOS-ACS-FR-SW2-F0 (or F1) - Armoured Collectively Screened Reduced Halogen Fire Resistant, TRATOS-ACS-FR-SW4-F0 (or F1) - Armoured Collectively Screened Halogen Free

TRATOS-AIS-FR-SW2-F0 - TRATOS-AIS-FR-SW4-F0

TRATOS-AIS-FR-SW2-F0 (or F1) - Armoured Individually Screened Reduced Halogen Fire Resistant, TRATOS-AIS-FR-SW4-F0 (or F1) - Armoured Individually Screened Halogen Free Fire Resistant

TRATOS-ACS-SW2 - TRATOS-ACS-SW4

TRATOS-ACS-SW2 - Armoured Collectively Screened Reduced Halogen, TRATOS-ACS-SW4 - Armoured Collectively Screened Halogen Free

TRATOS-AIS-SW2 - TRATOS-AIS-SW4

TRATOS-AIS-SW2 - Armoured Individually Screened Reduced Halogen, TRATOS-AIS-SW4 - Armoured Individually Screened Halogen Free

TRATOS-UCS-SW2 - TRATOS-UCS-SW4

TRATOS-UCS-SW2 - Unarmoured Collectively Screened Reduced Halogen, TRATOS-UCS-SW4 - Unarmoured Collectively Screened Halogen Free

TRATOS-UIS-SW2 - TRATOS-UIS-SW4

TRATOS-UIS-SW2 - Unarmoured Individually Screened Reduced Halogen, TRATOS-UIS-SW4 - Unarmoured Individually Screened Halogen Free