Tratos Rolling stock cables are used extensively to wire Power, Control and Communication circuits and systems in both railway and mass transit rolling stock. Locomotive, power car or passenger carriage in high speed intercity trains, commuter trains, diesel or electric motive power there is a Tratos Rolling Stock cable to suit every application.

TRATOS RS HT (EF)

HIGH TEMPERATURE POWER CABLES

3,6/6 kV – single core with extra flexible conductor. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits, inter coaches power circuits.

Construction

Conductor

extra flexible tinned annealed copper wires

(plain copper only for 150° C core temperature)

class 6 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 111)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-HT

HIGH TEMPERATURE POWER CABLES

1,8/3 or 3,6/6 kV – sheathed single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits.

Construction

Conductor

flexible tinned annealed copper wires

(plain copper only for 150° C core temperature)

class 5 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 112)

Outer sheath

LSZH elastomeric compound according to EN 50382-1

(EM 105, EM 106 or EM 107)

Black (other colours if required)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-HT

HIGH TEMPERATURE POWER CABLES

1,8/3 or 3,6/6 kV – single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits.

Construction

Conductor

flexible tinned annealed copper wires

(palin copper only for 150° C core temperature)

class 5 according to BS EN 60228

Insulation

silicon rubber according to EN 50382-1 (EI 111)

Standards

EN 50382

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-MW

MEDIUM WALL POWER AND CONTROL CABLES

0,6/1 kV – screened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Overal screen

tinned annealed copper wires with required diameter

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-MW

MEDIUM WALL POWER AND CONTROL CABLES

1,8/3 or 3,6/6 kV – sheathed single core with reduced dimensions. Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

screen (only for 3,6/6 kV) conductive tape or extruded conductive layer

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 106 to EI 109)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 3 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-MW

MEDIUM WALL POWER AND CONTROL CABLES

0,6/1 or 1,8/3 kV – unscreened insulated single core with reduced dimensions. Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Standards

EN 50264 – 3 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS SS-SW

STANDARD WALL POWER AND CONTROL CABLES

300/500 V or 0,6/1 kV – screened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Overal screen

tinned annealed copper wires with required diameter

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 2

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-SW

STANDARD WALL POWER AND CONTROL CABLES

300/500 V or 0,6/1 kV – unscreened multicore. Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, lighting circuits, auxiliary and electric heating circuits, control and monitoring circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 105)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 2

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS US-SW

STANDARD WALL POWER AND CONTROL CABLES

1,8/3 or 3,6/6 kV – sheathed single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Outer sheath

LSZH elastomeric compound according to EN 50264-1

(EM 101 to EM 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

TRATOS RS UU-SW

STANDARD WALL POWER AND CONTROL CABLES

0,6/1 or 1,8/3 kV – unscreened insulated single core. Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits.

Construction

Conductor

flexible tinned annealed copper wires

class 5 according to BS EN 60228

Insulation

LSZH elastomeric compound according to EN 50264-1

(EI 101 to EI 104)

Black (other colours if required)

Standards

EN 50264 – 2 – 1

EN 50305

EN 50355

IEC 60332-1-2 Flame propagation

IEC 60332-3-22 Vertical flame spread

IEC 61034 Smoke emission density

IEC 60754 Halogen acid gas content

Cables

TRATOS RS HT (EF)

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits, inter coaches power circuits

TRATOS RS US-HT

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits

TRATOS RS UU-HT

Special fire performance, low smoke emmision, corrosivity and toxitity. Traction and power circuits

TRATOS RS US-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Inboard safety circuits, control and monitoring circuits, lighting circuits, auxiliary and electric heating circuits

TRATOS RS US-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Medium Voltage auxiliary circuits, power circuits, Medium Voltage heating circuits

TRATOS RS UU-MW

Special fire performance, low smoke emmision, corrosivity and toxitity. Lighting circuits powered by batteries, control and monitoring circuits, auxiliary and electric heating circuits, power circuits

Track Feeder cable

Tratos have many years of experience supplying flexible cables to withstand the most physically demanding of environments.

Station & Premises

Tratos are able to supply a complete range of Fire Performance cables to meet the most stringent requirements for buildings and underground installations.

Signalling power & control cable

Tratos are an Internationally recognised supplier of LV Power and Control cables for the European Rail Industry

Signalling power & control cable

Tratos are an Internationally recognised supplier of LV Power and Control cables for the European Rail Industry

Pantograph Power Cable

The standard range of pantograph cables manufactured by Tratos are rated at 26 kV and 45 kV.

Overhead line equipment cable

Overhead line equipment cables are a vitally important component in earth bonding systems

MV AND HV CABLE

Tratos MV and HV cables are used to connect railway substations to the Distribution Network Operator (DNO).

Data & Telecommunications

Tratos manufactures an extensive range of both copper and fibre communication & data cables

Data & Telecommunications

Tratos manufactures an extensive range of both copper and fibre communication & data cables