Tratos have a long experience in the manufacture of fire resistant cables, including several major projects such as the Centre Court at Wimbledon, Caerphilly Hospital and London Underground Kings Cross St. Pancras.

TRATOS FIRESAFE-OPTI®

Fibre Optics - LOW SMOKE ZERO HALOGEN (LSZH) CABLES having enhanced circuit integrity when exposed to fire

Firesafe OPTI has been designed for use in areas where optical fibre cables are required to operate in the event of a fire. For use in railway and highways tunnels, mass transit underground systems, metro lines, ducts and public buildings.

Construction

Fibre: 62.5/125 multimode fibres

Tube: jelly filled loose tube

Tape: Fire Resistant Wrapping

Inner Sheath: polyethylene

Strength Member: aramidic

Tape: corrugated steel

Outer Sheath: LSZH

Standard Colour: violet (more colors are available upon request)

CEI IEC 60331-11 Ed. 1999 equivalent CEI 20-36/1-1 Ed. 1 2003-03: Test for electric cables under re conditions Part 11 apparatus fire alone at flame temperatures of at least 750°C

CEI OEC 60331-25 Ed. 1999 equivalent CEI 20-36/2-5 Ed. 1 2002-03: Test for electrical cables under fire conditions – circuits integrity part 25 procedures and requirements optical bre cables

TRATOS FIRESAFE-SWA/M1®

600/1000 V Armoured - Low Smoke Zero Halogen (Lszh) Cables having Enhanced Circuit Integrity when exposed to fire - Based on BS7846

Firesafe SWA/M1 is designed for installations where a fire situation may pose a hazard and the maintenance of circuit integrity is a requirement. Applications include internal and external use in public buildings, schools, hospitals, department stores, cinemas, hotels, theatres, computer centres and similar applications where an armoured “enhanced” grade cable is specified for use in the applicable Code of Practice: BS 5266 Emergency lighting cables – enhanced, BS 5839 Clause 26.2e Enhanced grade, BS 8519 Category 1, 2  and 3 (when tested in Tratos laboratories; pending third party approval).

Construction

Conductor: stranded plain annealed copper class 1 or class 2 conductor

Tape: mica/glass fire barrier tape

Insulation: extruded cross-linked polymer

Bedding: thermoplastic LSZH compound

Armour: single layer of galvanised steel wires

Sheath: thermoplastic LSZH sheathing compound

Standard Colours: black

Identification of Core
2 core: Brown, Blue

3 core: Brown, Black, Grey

4 core: Brown, Blue, Black, Grey Multicore: Black core with white printed numbering

BS 7846 F2; Manufacturing and test standard

BS 6387; Categories C, W & Z

BS 8434-2 enhanced

BS EN 50200; PH30, PH60, PH120

BS 8491; PH30, PH60, PH120*

BS EN 60332-1 and BS EN 60332-3; Flame propagation

BS EN 50267; Acid gas emission

BS EN 61034; Smoke emission

TRATOS FIRESAFE-TW950e®

300/500 V - Low Smoke Zero Halogen (Lszh) Cables having Enhanced Circuit Integrity when exposed to fire - Based on BS7629

Firesafe TW950e is designed for installations where a fire situation may pose a hazard and the maintenance of circuit integrity is a requirement. Applications include public buildings, schools, hospitals, department stores, cinemas, hotels, theatres, computer centres and similar applications where “enhanced” grade cable is specified for use in the applicable Code of Practice: BS 5266 Emergency lighting cables – enhanced, BS 5839 Clause 26.2e Enhanced grade, BS 8519 Category 1, 2  and 3 (when tested in Tratos laboratories; pending third party approval).

Construction

Conductor: stranded plain annealed copper class 1 or class 2 conductor

Insulation: extruded silicone rubber

Tape: Open weave glass fire barrier tape

Electrostatic Screen: laminated aluminium foil in direct contact with a tinned annealed copper drain wire

Sheath: thermoplastic LSZH sheathing compound

Standard Colours: red or white

Identification of Core
2 core + bare earth: Brown, Blue
3 core + bare earth: Brown, Black, Grey
4 core + bare earth: Brown, Blue, Black, Grey

Marking: TW950E +TRATOS+ BASEC BS 7629-1 BS 6387 CWZ LPCB222b/01 BS 5839-1 PH120  2X2,5+E  LOT/YEAR -METRE MARKING – “CE”

BS 7629; Manufacturing standard

BS 6387; Categories C, W & Z

BS 8434-2 enhanced

BS EN 50200; PH30, PH60, PH120

BS EN 60332-1 and BS EN 60332-3; Flame propagation

BS EN 50267; Acid gas emission

BS EN 61034; Smoke emission

TRATOS FIRESAFE-TW950s®

300/500 V - Low Smoke Zero Halogen (Lszh) Cables having STANDARD Circuit Integrity when exposed to fire - Based on BS7629

Firesafe TW950s is designed for installations where a fire situation may pose a hazard and the maintenance of circuit integrity is a requirement. Applications include public buildings, schools, hospitals, department stores, cinemas, hotels, theatres, computer centres and similar applications where “standard” grade cable is specified for use in the applicable Code of Practice: BS 5266 Emergency lighting cables – standard, BS 5839 Clause 26.2d Standard grade, BS 8519 Category 1 and 2 (When tested in Tratos laboratories; pending third party approval).

Construction

Conductor: solid or stranded plain annealed copper class 1 or class 2 conductor

Insulation: extruded silicone rubber

Electrostatic Screen: laminated aluminium foil in direct contact with a tinned annealed copper drain wire

Sheath: thermoplastic LSZH sheathing compound

Standard Colours: red or white

Identification of Core 
2 core + bare earth: Brown, Blue
3 core + bare earth: Brown, Black, Grey
4 core + bare earth: Brown, Blue, Black, Grey

Marking: TW950 +TRATOS+  BASEC  BS7629-1 BS6387 CWZ LPCB222a/01 BS5839-1 PH30 2X1,5+E  LOT/YEAR -METRE MARKING – “CE”

BS 7629; Manufacturing standard

BS 6387; Categories C, W & Z

BS EN 50200; PH30 (30 minutes annex E)

BS EN 60332-1 and BS EN 60332-3; Flame propagation

BS EN 50267; Acid gas emission

BS EN 61034; Smoke emission

TRATOS FIRESAFE-TW100®

450/750V - Low Smoke Zero Halogen (Lszh) Cables having Enhanced Circuit Integrity when exposed to fire - Based on BS7211

Firesafe TW100 is designed for installations where a fire situation may pose a hazard and the maintenance of circuit integrity is a requirement. Firesafe TW100 is suitable for installations in onerous conditions where the cable is mechanically protected in metal conduit or trunking. Applications include public buildings, schools, hospitals, department stores, cinemas, hotels, theatres, computer centres and similar applications where “standard” grade cable is specified for use in the applicable Code of Practice: BS 5266 Emergency lighting cables, standard and enhanced, when enclosed in screwed steel conduit.

Construction

Conductor: stranded plain annealed copper class 1 or class 2 conductor

Insulation: mica-glass fire resistant tape covered by an extruded layer of cross-linked, LSZH insulating compound

Standard Colours: red, black, blue, yellow, brown, green/yellow (other colours on request)

Identification of Core: by colour

Marking: TW100 +TRATOS+  BASEC  BS7629-1 BS6387 CWZ BS5839 cross section LOT/YEAR -METRE MARKING – “CE”

BS 7211 Manufacturing standard with an additional mica-glass fire resistant tape.

BS 6387; Categories C, W & Z (when applied to a single cable)

IEC 60331; with the flame temperature increased to 950 oC

BS EN 50200: when installed in screwed steel conduit

BS EN 50200 Annex E: when installed in screwed steel conduit

BS EN 60332-1 and BS EN 60332-3; Flame propagation

BS EN 50267; Acid gas emission

BS EN 61034; Smoke emission

Cables

TRATOS FIRESAFE-OPTI®

Fibre cables operating in the event of a fire

TRATOS FIRESAFE-SWA/M1®

Firesafe SWA/M1 is designed for fire situations

TRATOS FIRESAFE-TW950e®

Firesafe TW950e is designed for fire situations

TRATOS FIRESAFE-TW950s®

Firesafe TW950s is designed for fire situations

TRATOS FIRESAFE-TW100®

Firesafe TW100 is designed for fire situations

TRATOS-JBA-MVA-FR-SHF2

Armoured Halogen Free - Fire Resistant- Mud Resistant

TRATOS-JBA-MVA-SHF2

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-A-FR-SHF2 - 0,6/1 kV

Armoured Halogen Free - Fire Resistant - Mud Resistant

TRATOS-JBA-A-SHF2 - 0,6/1 kV

Armoured Halogen Free - Mud Resistant

TRATOS-JBA-U-SHF2

Unarmoured Halogen Free - Mud Resistant