TRATOS’ shipboard cables are an exceptionally high quality, cost-effective solution for ship yards. Lightweight, easy and less expensive to install and operate.

TRATOS MARINE AMV - 8,7/15 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 8,7/15 kV (Umax = 17,5KV)

Construction

Tinned copper conductor (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 8.7/15 kV – IEC 60332-3-22 – year + metre marking

EC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AMV - 6/10 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 6/10 kV (Umax = 12KV)

Construction

Tinned copper conductor Cl.2 (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 6/10 kV – IEC 60332-3-22 – year + metre marking

EC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AMV - 3,6/6 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 3,6/6 kV (Umax = 7,2KV)

Construction

Tinned copper conductor Cl.2 (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 3,6/6 kV – IEC 60332-3-22 – year + metre marking

IEC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE ACS-FR

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE ACS-FR – (Armoured Collectively Screen-Fire Resistant) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/ polyestere tape with stranded tinned copper wire drain wire

Inner covering: Synthetic tape or halogen free compound when necessary

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – ACS – FR – no.xcsa – 250V – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

IEC 60092-376 Design guideline

IEC 60092351-359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

IEC 60331-11 and IEC 60331-21 Fire resistance

TRATOS MARINE AIS - TRATOS MARINE AICS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE AIS – (Armoured Individual Screen) 60 V – 250 V | TRATOS MARINE AICS – (Armoured Individual & Collective Screen) 60 V – 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Indiv. or indiv & collective aluminium/ polyester tape with drain wire stranded tinned copper

Inner covering: Synthetic tape or halogen free compound when necessary

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AICS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE ACS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE ACS – (Armoured Collective Screen) 60 V | TRATOS MARINE ACS – (Armoured Collective Screen) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/ polyester tape with drain wire stranded tinner copper

Inner covering: Synthetic tape

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – ACS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UIS - TRATOS MARINE UICS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UIS – (Unarmoured Individual Screen) 60 V – 250 V | TRATOS MARINE UICS – (Unarmoured Individual & Collective Screen) 60 V – 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation: XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Indiv. or indiv & collective alum/ polyester tape with drain wire stranded tinned copper

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – UIS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UCS 60V - 250V

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UCS – (Unarmoured Collective Screen) 60 V – TRATOS MARINE UCS – (Unarmoured Collective Screen) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/polyester tape with drain wire stranded tinned copper

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – UCS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AFR - TRATOS MARINE FAFR

ARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE AFR – (Armoured Fire Resistant) 0,6/1kV | TRATOS MARINE FAFR – (Flexible conductor Armoured Fire Resistant) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Filler: Halogen free compound (if necessary)
Inner covering: SHF1 Halogen-free thermoplastic sheath

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AFR – no.xcsa – 0,6/1 kV – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60331-11 and IEC 60331-21 Fire resistance

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UFR - TRATOS MARINE FUFR

UNARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UFR – (Unarmoured Fire Resistant) 0,6/1kV | TRATOS MARINE FUFR – (Flexible conductor Unarmoured Fire Resistant) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Filler:  Halogen free compound (when necessary)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking:  TRATOSMARINE – UFR – no.xcsa – 0,6/1 kV – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60331-11 and IEC 60331-21 Fire resistance

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE A - TRATOS MARINE FA

ARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE A – (Armoured) 0,6/1kV | TRATOS MARINE FA – (Flexible conductor Armoured) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2
(cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Filler: Halogen free compound (when necessary)

Inner covering: SHF1 Halogen-free thermoplastic sheath

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – A – no.xcsa – 0,6/1 kV – IEC 60332-3-22 – year + metre marking

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE U - TRATOS MARINE FU

UNARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE U – (Unarmoured) 0,6/1kV | TRATOS MARINE FU – (Flexible conductor Unarmoured) 0,6/1kV

Construction

Conductor:  Plain (tinned when request) annealed copper cl. 2 (class 5 when request) acc. to IEC 60228

Insulation:   XLPE

Filler: Halogen free compound (when necessary)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – U – no.xcsa – 0,6/1 kV – IEC 60332-3-22 – year + metre marking

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

Cables

TRATOS MARINE AMV - 8,7/15 kV

TRATOS MARINE AMV - 8,7/15 kV (Umax = 17,5KV)

TRATOS MARINE AMV - 6/10 kV

TRATOS MARINE AMV - 6/10 kV (Umax = 12KV)

TRATOS MARINE AMV - 3,6/6 kV

TRATOS MARINE AMV - 3,6/6 kV (Umax = 7,2KV)

TRATOS MARINE ACS-FR

TRATOS MARINE ACS-FR - (Armoured Collectively Screen-Fire Resistant) 250 V

TRATOS MARINE AIS - TRATOS MARINE AICS

TRATOS MARINE AIS - (Armoured Individual Screen) 60 V - 250 V | TRATOS MARINE AICS - (Armoured Individual & Collective Screen) 60 V - 250 V

TRATOS MARINE ACS

TRATOS MARINE ACS - (Armoured Collective Screen) 60 V | TRATOS MARINE ACS - (Armoured Collective Screen) 250 V