Tratos is a long-established manufacturer of Telecommunication Cables, a family of cables used for the transmission of Data, Information, Voice and Images. Production at Tratos covers almost all the installation needs of Telecommunication Cabling.

Indoor - DSL Screened Cables

Construction

Conductor: Plain copper 0.4 to 0.5 mm
Insulation: Solid PE or foam skin PE
Cabling: Pair, unit of 4 or 24 pairs, bundles of 24 or 32 pairs
Size: Up to 96 or 128 pairs
Screen/Braid:AluminiumPolyester tape with tinned copper wire braid
Outer sheath:Low Smoke Zero Halogen

Indoor - Subscriber wire

Construction

Conductor: Copper 0.4 to 0.9 mm
Insulation: Solid PE
Size: 1 pair or 1 quad
Sheath: PVC (loose tube)

Indoor - Jumper wire

Construction

Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Size: 1 to 7 wires

Indoor - Distribution

Construction

Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Cabling: Pair or quad; unit and sub-unit
Size: 1 to 400 pairs
Screen: Polyester plated aluminium tape
(if required)
Sheath: PVC  or LSZH

Aerial - DSL Drop

Construction

Conductor: Plain copper 0.6 mm
Insulation: Solid PE
Size: 2 to 4 pairs
Water penetration: Filling compound
(if required)
Strenght member: Aramid
Outer Sheath: PE

Aerial - Drop wire

Construction

Conductor: Bronze 1mm
Insulation: Solid PE
Size: 1 pair
Sheath: PVC

Aerial - Circular

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound
(if required )
Screen/moisture barrier: Wrapped aluminium tapes or Aluminium/Polyester tapes
Sheath: PE

Aerial

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound
(if required)
Screen/moisture barrier: Wrapped aluminium tapes Aluminium/Polyester tape
Sheath: PE
Supporting cord: Steel wires

Underground - In ducts

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if required)
Moisture barrier: Aluminium polyester tape
Sheath: PE

Underground - Buried Steel wires armouring

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if required)
Moisture barrier: Aluminium polyester tape
Sheath: PE
Armouring: Steel wires
Outer sheath PE or  PVC

Underground - Buried Corrugated Aluminium tapes armouring

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if required)
Moisture barrier: Aluminium/Polyester tape
Sheath: PE
Armouring: Corrugated steel tapes
Outer sheath: PE or  PVC

Underground - Buried steel tapes Armouring

Construction

Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound (if required)
Moisture barrier: Aluminium/Polyester tape
Sheath: PE
Armouring: Helical steel tapes
Outer sheath: PE or PVC

Cables

Indoor - DSL Screened Cables

Conductor: Plain copper 0.4 to 0.5 mm - Insulation: Solid PE or foam skin PE

Indoor - Subscriber wire

Conductor: Copper 0.4 to 0.9 mm - Insulation: Solid PE - Size: 1 pair or 1 quad

Indoor - Jumper wire

Conductor: Tinned copper 0.4 to 0.9 mm - Insulation: PVC - Size: 1 to 7 wires

Indoor - Distribution

Conductor: Tinned copper 0.4 to 0.9 mm - Insulation: PVC - Cabling: Pair or quad; unit and sub-unit

Aerial - DSL Drop

Conductor: Plain copper 0.6 mm - Insulation: Solid PE - Size: 2 to 4 pairs

Aerial - Drop wire

Conductor: Bronze 1mm - Insulation: Solid PE

CW1280 POLYQUAD

Conductor: Plain copper 0.63 to 0.9 mm - Insulation: Solid, foam-skin, cellular PE

CW1280/1252 Aerial PET-PEQ

Conductor: Plain copper 0.5 to 0.9 mm - Insulation: Solid, foam-skin, cellular PE

CW 1326/1224/1179 PEUT Underground - In ducts

Conductor: Plain copper 0.4 to 0.9 mm - Insulation: Solid, foam-skin, cellular PE

CW1128/1198 PET Steel Wire Armoured

Conductor: Plain copper 0.5 to 0.9 mm - Insulation: Solid, foam-skin, cellular PE

Indoor - Subscriber wire

Conductor: Copper 0.4 to 0.9 mm - Insulation: Solid PE - Size: 1 pair or 1 quad

Indoor - Jumper wire

Conductor: Tinned copper 0.4 to 0.9 mm - Insulation: PVC - Size: 1 to 7 wires