Marine Cables

TRATOS’ shipboard cables are an exceptionally high quality, cost-effective solution for ship yards. Lightweight, easy and less expensive to install and operate.

TRATOS MARINE AMV - 8,7/15 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 8,7/15 kV (Umax = 17,5KV)

Construction

Tinned copper conductor (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 8.7/15 kV – IEC 60332-3-22 – year + metre marking

Standards

EC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AMV - 6/10 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 6/10 kV (Umax = 12KV)

Construction

Tinned copper conductor Cl.2 (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 6/10 kV – IEC 60332-3-22 – year + metre marking

Standards

EC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AMV - 3,6/6 kV

POWER MEDIUM VOLTAGE - LOW SMOKE HALOGEN FREE

TRATOS MARINE AMV – 3,6/6 kV (Umax = 7,2KV)

Construction

Tinned copper conductor Cl.2 (Cl. 5 upon request)

Semiconducting layer

HEPR insulation or XLPE

Semiconducting layer

Copper tape shield

Extruded filler halogen free (If necessary)

Synthetic tape

Inner covering SHF1 Halogen-free thermoplastic sheath

Tinned copper braid armour

Outer sheath SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AMV – no.xcsa – 3,6/6 kV – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-354; IEC 60092-350 Design guideline

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE ACS-FR

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE ACS-FR – (Armoured Collectively Screen-Fire Resistant) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/ polyestere tape with stranded tinned copper wire drain wire

Inner covering: Synthetic tape or halogen free compound when necessary

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – ACS – FR – no.xcsa – 250V – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-376 Design guideline

IEC 60092351-359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

IEC 60331-11 and IEC 60331-21 Fire resistance

TRATOS MARINE AIS - TRATOS MARINE AICS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE AIS – (Armoured Individual Screen) 60 V – 250 V | TRATOS MARINE AICS – (Armoured Individual & Collective Screen) 60 V – 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Indiv. or indiv & collective aluminium/ polyester tape with drain wire stranded tinned copper

Inner covering: Synthetic tape or halogen free compound when necessary

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AICS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE ACS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE ACS – (Armoured Collective Screen) 60 V | TRATOS MARINE ACS – (Armoured Collective Screen) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/ polyester tape with drain wire stranded tinner copper

Inner covering: Synthetic tape

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – ACS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UIS - TRATOS MARINE UICS

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UIS – (Unarmoured Individual Screen) 60 V – 250 V | TRATOS MARINE UICS – (Unarmoured Individual & Collective Screen) 60 V – 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation: XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Indiv. or indiv & collective alum/ polyester tape with drain wire stranded tinned copper

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – UIS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UCS 60V - 250V

TELECOMUNICATIONS AND INSTRUMENTATION CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UCS – (Unarmoured Collective Screen) 60 V – TRATOS MARINE UCS – (Unarmoured Collective Screen) 250 V

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Lay up: Assembled pairs/ triples/ quads

Shield: Aluminium/polyester tape with drain wire stranded tinned copper

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – UCS – no.xcsa – Voltage – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092-370 Design guideline

IEC 60092-376 Design guideline

IEC 60092351; -359 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE AFR - TRATOS MARINE FAFR

ARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE AFR – (Armoured Fire Resistant) 0,6/1kV | TRATOS MARINE FAFR – (Flexible conductor Armoured Fire Resistant) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Filler: Halogen free compound (if necessary)
Inner covering: SHF1 Halogen-free thermoplastic sheath

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – AFR – no.xcsa – 0,6/1 kV – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60331-11 and IEC 60331-21 Fire resistance

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE UFR - TRATOS MARINE FUFR

UNARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE UFR – (Unarmoured Fire Resistant) 0,6/1kV | TRATOS MARINE FUFR – (Flexible conductor Unarmoured Fire Resistant) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 60228

Insulation:  Mica tape and XLPE

Filler:  Halogen free compound (when necessary)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking:  TRATOSMARINE – UFR – no.xcsa – 0,6/1 kV – IEC 60331-21 – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60331-11 and IEC 60331-21 Fire resistance

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE A - TRATOS MARINE FA

ARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE A – (Armoured) 0,6/1kV | TRATOS MARINE FA – (Flexible conductor Armoured) 0,6/1kV

Construction

Conductor: Plain (tinned when request) annealed copper cl. 2
(cl.5 when request) acc. to IEC 60228

Insulation:  XLPE

Filler: Halogen free compound (when necessary)

Inner covering: SHF1 Halogen-free thermoplastic sheath

Armour: Plain copper wire braid (tinned when requested)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – A – no.xcsa – 0,6/1 kV – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

TRATOS MARINE U - TRATOS MARINE FU

UNARMOURED POWER and CONTROL CABLES - LOW SMOKE HALOGEN FREE

TRATOS MARINE U – (Unarmoured) 0,6/1kV | TRATOS MARINE FU – (Flexible conductor Unarmoured) 0,6/1kV

Construction

Conductor:  Plain (tinned when request) annealed copper cl. 2 (class 5 when request) acc. to IEC 60228

Insulation:   XLPE

Filler: Halogen free compound (when necessary)

Sheath: SHF1 Halogen-free thermoplastic sheath

Marking: TRATOSMARINE – U – no.xcsa – 0,6/1 kV – IEC 60332-3-22 – year + metre marking

Standards

IEC 60092350-353 Design guide

IEC 60092-360 Materials

IEC 60332-1-2 and IEC 60332-3-22 Flame retardance

IEC 60754-1 and IEC 60754-2 Halogen free properties

IEC 61034-1 and IEC 61034-2  Smoke emission

Cables

TRATOS MARINE AMV - 8,7/15 kV

TRATOS MARINE AMV - 8,7/15 kV (Umax = 17,5KV)

TRATOS MARINE AMV - 6/10 kV

TRATOS MARINE AMV - 6/10 kV (Umax = 12KV)

TRATOS MARINE AMV - 3,6/6 kV

TRATOS MARINE AMV - 3,6/6 kV (Umax = 7,2KV)

TRATOS MARINE ACS-FR

TRATOS MARINE ACS-FR - (Armoured Collectively Screen-Fire Resistant) 250 V

TRATOS MARINE AIS - TRATOS MARINE AICS

TRATOS MARINE AIS - (Armoured Individual Screen) 60 V - 250 V | TRATOS MARINE AICS - (Armoured Individual & Collective Screen) 60 V - 250 V

TRATOS MARINE ACS

TRATOS MARINE ACS - (Armoured Collective Screen) 60 V | TRATOS MARINE ACS - (Armoured Collective Screen) 250 V

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok