Tratos Limited
Knowsley
– School Lane –
Knowsley
– Merseyside –
L34 9HD
[T]: 0151 548 3888
[F]: 0151 549 1169
License Number: 048
Mark & Thread:
Origin Mark: x TRATOS x
Origin Thread: BROWN/GREY/ORANGE/YELLOW
Systems Certification:
Certification Number: CS1-043
Standard: BS EN ISO 9001:2008
Comments: The design, manufacture and supply of the following cable types and products: Flexible Cables and Cords. Instrumentation and Control Cables. Power Cables Rated up to 600/1000V. Insulation and Sheathing Materials used on above – PVC, PE, TPE, XLPE, Fluropolymer and Low Smoke & Fume Zero Halogen.
Products:
Standard: BS 4553-1:1998 Incorporating Amendment Nos. 1 & 2
Table Number: 3
Licence: 048/001/156
Range
4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Sheath – TM1. Insulation – TI1.
Standard: BS 5467:1997 & A3:2008
Table Number: 10
Licence: 048/001/162
Range
1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath – Type 9. Insulation – GP8.
Standard: BS 5467:1997 & A3:2008
Table Number: 6
Licence: 048/001/162
Range
1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath – Type 9. Insulation – GP8.
Standard: BS 5467:1997 & A3:2008
Table Number: 8
Licence: 048/001/162
Range
1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath – Type 9. Insulation – GP8.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 4a
Licence: 048/001/165
Range
1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Stranded conductors. Single-core. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 4b
Licence: 048/001/157
Range
Flexible Conductor Cables – Plain annealed copper conductors. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 4b
Licence: 048/001/158
Range
Flexible Conductor Cables – Plain annealed copper conductors. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 5
Licence: 048/001/159
Range
1.0sqmm nominal cross-sectional area of conductor inclusive. Solid conductors. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 5
Licence: 048/001/161
Range
0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Flexible conductors. Single-core. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 5
Licence: 048/001/160
Range
0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Flexible conductors. Single-core. Insulation – TI1.
Standard: BS 6004:2000 Incorporating Amendment Nos. 1 & 2
Table Number: 7
Licence: 048/001/155
Range
Copper Conductor Cables – 1.0sqmm – 35sqmm nominal cross-sectional areas of conductor inclusive. Single core. Sheath – Type 6. Insulation – TI1.
Standard: BS 7211:1998 Incorporating Amendments Nos. 1 & 2
Table Number: 3a
Licence: 048/001/164
Range
1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation – EI5
Standard: BS 7211:1998 Incorporating Amendments Nos. 1 & 2
Table Number: 3b
Licence: 048/001/163
Range
1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 flexible conductor. Insulation – EI5