500 hours of artificial weathering 5GM3 DIN VDE 0207 Teil 21

Tratos, thanks to its specialized laboratory compounds Tramet, today merged into TRATOS HV, has developed a new UV resistant compound.

The test carried out on a cable media has given excellent results.

The test was performed by the IMQ-‘according to HD 605 S “.

One sample of sheath has been taken, to provide 6 test pieces for the Tensile tests without aging, and 6 test pieces for each of the tensile tests after aging Standard according to IEC 60811-1-1 clause 9.2, the artificial weathering tests, has obtained a varaition Maximum Tensile strength after ressitance to UV rays of -12.3% as medium value, and a Maximum Variation Elongation at break after ressitance to UV rays of -6.8% as Medium value.

“Trying to be improved to give a good product to the customer, this has always been the real goal of Tratos, since its foundation.”

 