Tratos® MULTIPAIR – PVC SHEATHED
Low voltage multicore power and control cable to BS 7870 8.2 and ENATS 09-6
Tratos® MULTIPAIR – 0.6/1 KV – PVC SHEATHED
LV polyethylene insulated multipair cables for use by distribution and generation utilities for control, data or telecommunication applications to BS 7870 8.2 and ENATS 09-6.
Conductor – solid round (class 1) 1/0.8mm plain copper conforming to the requirements of BS EN 60288
Conductor Insulation – Polyethylene grade L/MD BS EN 50290-2-23. Insulated conductor formed in to pairs with a maximum lay length of 150mm. Polyethylene bedded grade LD BS EN 50290-2-24. Single wire galvanised armour.
- Oversheath – PVC Type TM 1 conforming to the requirements given in BS EN 50363-4-1
- Colour – Black (other colours can be supplied on request).
- Cables available in either a filled (PJ) or un-filled version.
- Induced voltage up to 5kV BS 7870 8.2 table 1and ENATS 09-6 table E.2 (a). Induced voltage up to 15kV BS 7870 8.2 table 2and ENATS 09-6 table E.2 (b).
- Standard configurations available (other sizes available on request), 7 pair, 19 pair, 37 pair and 61 pair.
STANDARDS
- BS 7870-8.2 (implements HD 627 3A2) and ENA Technical Specification 09-6
- BS 7870-1
- BS EN 60228
- BS EN 50290-2-23
- BS EN 50290-2-24
- BS EN 50363-4-1
Contact us:
Tel: +44 20 3148 5178
e-mail: sales@tratosgroup.com
Please don’t hesitate to contact us if you need additional information about our products.
Catalogues
Brochure Tratos Energy DNOs BS7870
Application
Low Voltage control, data and telecommunication multi-pair armoured cable for use by the Distribution Network Operators (DNO's) and Independent Distribution Network Operators (IDNO's) primarily for use underground in wet conditions provided the “filled” option is used. Provided the appropriate design is used suitable for running alongside of high voltage cables and also withstanding high levels of inducted voltage. Note: These cables may be used indoors but they should not be used where fire propagation is a risk or where the emission of corrosive fumes and excessive smoke in the event of a fire is forbidden.CONSTRUCTION
- Conductor – solid plain annealed copper (Class 1)
- Insulation – Polyethylene grade L/MD BS EN 50290-2-23.
- Assembly of cores – 2 cores twisted to form a pair, pairs laid up in concentric layers, filled or unfilled with a suitable compound as specified by the customer
- Bedding – Polyethylene grade LD BS EN 50290-2-24.
- Armouring – Single helical layer of galvanised steel or aluminium wires
- Oversheath – PVC Type TM1 Black
- Colour – Black (other colours can be supplied on request)
- Marking – TRATOS ELECTRIC CABLE TELE (unfilled) or TELE F (filled) BS 7870-8.2 (Year of Manufacture)
Standards
Technical Specifications
- Conductor – Stranded copper class 2 to BS EN 60288
- Insulation – Polyethylene grade L/MD BS EN 50290-2-23
- Bedding – Polyethylene grade LD BS EN 50290-2-24
- Sheath – Type TM1 to BS EN 50363-4-1
Contact us
Please, don’t hesitate to contact us for additional information on our company or our products.
Related Case Studies
Other News
-
Egidio Capaccini Award 2024 edition
-
Tratos Cavi acquires AFL Telecommunications GmbH's German Plant
-
Tratos Visits CEECATL-China
-
Tratos Group Leaders Participated in ROG.e 2024 in Brazil
-
Tratos Receives Aenor Third-Party Certification for Gender Equality
-
Tratos Cavi, Italian Multinational Leader in the Sector, Acquires Endurance Telnet, Dedicated to Fibre Optic Cable Production
-
Tratos Announces Strategic Expansions and Technological Innovations
-
Tratos Cavi and Pfisterer's Joint Effort in Railway Innovation