TRATOS® Kynar-HMWPE Armoured
Cathodic Protection Cable
Kynar insulated, High Molecular Weight Polyethylene (HMWPE) inner sheath, Galvanised steel wire armour, High Molecular Weight Polyethylene (HMWPE) iuter sheath, single core cable.
The single core armoured cable is designed for use as the connecting cable in cathodic protection systems worldwide, the armour lends itself to direct burial installations.. A fluoropolymer, Polyvinylidene fluoride (PVDF), Trade name Kynar, is a tough engineering thermoplastic, well known for its excellent resistance to a wide range of chemicals, most acids and acid mixtures, weak bases, halogens, halogenated solvents, hydrocarbons, alcohols, salts and oxidants. Kynar has high dielectric strength and excellent mechanical properties over a wide temperature range leading to it becoming a popular choice as a reduced wall primary insulation. Kynar has low permeability leading to its choice for special applications such as cathodic protection where chlorine and hydrogen gasses could be present.
Immediately over the inner layer of Kynar Tratos, extrude an inner layer of High Molecular Weight Polyethylene (UHMW) and then apply a helical layer of Galvanised Steel wires. The outer sheath is a thick layer of High Molecular Weight Polyethylene (UHMW) which is a member of the thermoplastic polyethylene (PE) family. HMWPE is also known as high modulus polyethylene. HMWPE is a very tough material with the highest impact strength of all currently produced thermoplastics which, combined with its excellent abrasion and wear-resistant smooth outer surface, make it ideal as a sheath or outer covering for cables to be installed in arduous conditions.
HMWPE is resistant to concentrated acids, alkalis and other corrosive chemicals it is also resistant to many organic solvents. Like all Polyethylene’s HMWPE has excellent dielectric strength and electrical properties, as well as extremely low moisture absorption.
Tratos armoured Kynar/HMWPE cables offer high performance and reliability over an extended lifetime in arduous cathodic protection applications.
Contact us:
Tel: +44 20 3148 5178
e-mail: sales@tratosgroup.com
Please don’t hesitate to contact us if you need additional information about our products.
Application
Tratos Cathodic Protection Cables are single conductor cables that are intended to carry a DC current to anodes and cathodes in a cathodic protection system. Tratos Cathodic Protection Cables are designed for use in both active and passive cathodic protection systems to eliminate and prevent corrosion in Metals. Tratos Armoured Cathodic Protection Cables are intended for installation in arduous operating conditions where the risk o9f mechanical damage is higher than normal. Tratos Cathodic Protection Cables are used to eliminate and prevention the corrosion of steel pipelines and steel storage tanks, offshore oil and gas installations, offshore wind farms, ships and other maritime applications installed in air or water.Specifications
- Conductors: Plain annealed copper conductors – BS EN 60228 Class 2
- Insulation: Kynar- Polyvinylidene fluoride (PVDF)
- Inner Sheath: High Molecular Weight Polyethylene (HMWPE)
- Armour: Galvanised steel wire
- Outer Sheath: High Molecular Weight Polyethylene (HMWPE)
- Standard size range: 10mm2 to 50mm2 (up to 185mm2 available on request)
- Standard insulation colours are RED and BLACK
Standards
Technical Specifications
- Minimum ambient air temperature -55 oC
- Maximum continuous conductor temperature +105 oC
Minimum bending radius – Fixed Installation – 8D
Maximum allowable pulling tension:
- 50N/mm2 during installation
- 15N/mm2 in service
Additional Information
CONDUCTOR – Material: Compacted tinned annealed Cu
Nominal CSA | Nominal Diameter | Max. resistance 20oC |
mm2 | mm | Ω/km |
10 | 3.8 | 1.84 |
16 | 4.65 | 1.16 |
25 | 5.83 | 0.734 |
35 | 6.8 | 0.529 |
50 | 8 | 0.391 |
Nominal CSA | Nominal Diameter | Max. resistance 20oC |
mm2 | mm | Ω/km |
10 | 3.8 | 1.84 |
25 | 5.83 | 0.734 |
35 | 6.8 | 0.529 |
50 | 8 | 0.391 |
INSULATION – Material: XLPE
Nominal thickness | Nominal Diameter |
mm | mm |
0.7 | 5.2 |
0.7 | 6.05 |
0.9 | 7.63 |
0.9 | 8.6 |
1.0 | 10.0 |
Nominal thickness | Nominal Diameter |
mm | mm |
0.5 | 5.2 |
0.5 | 6.05 |
0.5 | 7.63 |
0.5 | 8.6 |
0.5 | 10.0 |
INNER SHEATH – Material: HDPE
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
ARMOUR – Material: Galvanised steel wires
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
OUTER SHEATH – Material: HDPE
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
Nominal thickness | Nominal Diameter | Nominal weight |
mm | mm | kg/km |
1.4 | 8.0 | 145 |
1.4 | 8.85 | 205 |
1.4 | 10.4 | 290 |
1.4 | 11.4 | 395 |
1.4 | 12.8 | 505 |
Contact us
Please, don’t hesitate to contact us for additional information on our company or our products.
Other News
-
Tratos Cavi acquires AFL Telecommunications GmbH's German Plant
-
Tratos Visits CEECATL-China
-
Tratos Group Leaders Participated in ROG.e 2024 in Brazil
-
Tratos Receives Aenor Third-Party Certification for Gender Equality
-
Tratos Cavi, Italian Multinational Leader in the Sector, Acquires Endurance Telnet, Dedicated to Fibre Optic Cable Production
-
Tratos Announces Strategic Expansions and Technological Innovations
-
Tratos Cavi and Pfisterer's Joint Effort in Railway Innovation
-
Tratos Cavi Spa has acquired AFL Telecommunications Europe Ltd in the UK