Tratos® – 11kV BS 7870 4.10
11kv Medium voltage cable single core or Triplex formation
11kV cable according to BS 7870
Medium Voltage 11kV polymeric insulated cables for use by distribution and generation utilities BS 7870-4.10.
- Conductor – Stranded plain annealed copper (class 2), Stranded aluminium (class 2) or solid aluminium (class 1).
- Conductor screen – Extruded layer of bonded semiconducting compound
- Insulation – XLPE Type DIX 3 or EPR type DIE 5 conforming to the requirements given in BS 7870-1 annex B.
- Insulation screen – Extruded layer of cold strippable semi-conducting compound (bonded can be supplied on request)
- Semi- conducting screens (conductor and insulation) and the insulation are applied by a continuous single pass triple extrusion.
- Metallic screen – single layer of plain annealed copper wires.
- Oversheath – Extruded layer of MDPE conforming to the requirements given in BS 7870-1 annex B for type DMP 5.
- Colour – Red for 11kV cables (other colours can be supplied on request)
For 11kV cables requiring to have a low emission of smoke and corrosive gases when affected by fire an oversheath of extruded thermoplastic LSZH material (DMZ 4) conforming to the requirements of BS 7870-1 annex B can be supplied in place of an MDPE sheath.
Voltage rating Uo/U 6.35/11kV.
This 11kV cables can be supplied as Single core or as 3 cores laid in a Triplex formation ( BS 7870-1 3.15)
Conductor sizes available, Aluminium conductor, 70mm, 95mm, 120mm, 150mm, 185mm, 240mm and 300mm. Copper conductor, 70mm, 95mm, 120mm, 150mm, 185mm, 240mm, 300mm, 400mm, 500mm, 630mm, 800mm and 1000mm.
STANDARDS
BS 7870-4-10 (implements Part 100 and Part 110 of HD 620 S2)
Contact us:
Tel: +44 20 3148 5178
e-mail: sales@tratosgroup.com
Please don’t hesitate to contact us if you need additional information about our products.
Catalogues
XLPE Medium Tension Cable – Spanish
Application
Medium Voltage energy distribution cable for use by the Distribution Network Operators (DNO's) and Independent Distribution Network Operators (IDNO's) to connect to local substations or small generation units. MDPE sheathed cables are typically used for direct burial or burial in ducts, DMZ 4 sheathed cables are typically used where the contribution of cables to a fire hazard require the use of cables with a low smoke zero halogen (LSZH) sheath.CONSTRUCTION
- Conductor: stranded circular compacted copper or aluminium
- Conductor screen: semi-conducting layer
- Insulation: HEPR or XLPE Insulation screen: strippable (alternatively bonded) semi-conducting screen copper wire spiral screen
- Outer sheath: HDPE sheathed
- Standard colour: RED
- Marking: TRATOS ELECTRIC CABLE 6.35/11 kV BS 7870-4.10 (Number of Cores and Size) + (Year of Manufacture) + Metre mark
Standards
Technical Specifications
- Conductor: Stranded plain annealed copper (class 2), Stranded aluminium (class 2) or solid aluminium (class 1) to BS EN 60228
- Insulation: XLPE type DIX 3 or EPR type DIE 5 to BS 7870-1, Annex B
- Sheath: Type A cables MDPE type DMP 5 to BS 7870-1, Annex B.
- Sheath: Type B cables LSZH type DMZ 4 to BS 7870-1, Annex B.
- Flame propagation on single cable (Type B cables only) BS EN 60332-1-2
- Flame propagation on multiple cables (Type B cables only) BS EN IEC 60332-3-24
- Smoke emission (Type B cables only) BS EN 61034
- Corrosive and acid gas (Type B cables only) BS EN IEC 60754
Contact us
Please, don’t hesitate to contact us for additional information on our company or our products.
Related Case Studies
Other News
-
Tratos Cavi Wins BTOB Award for Innovation
-
Egidio Capaccini Award 2024 edition
-
Tratos Cavi acquires AFL Telecommunications GmbH's German Plant
-
Tratos Visits CEECATL-China
-
Tratos Group Leaders Participated in ROG.e 2024 in Brazil
-
Tratos Receives Aenor Third-Party Certification for Gender Equality
-
Tratos Cavi, Italian Multinational Leader in the Sector, Acquires Endurance Telnet, Dedicated to Fibre Optic Cable Production
-
Tratos Announces Strategic Expansions and Technological Innovations
The 11kV cables are one of the voltage ratings listed in IEC 60038 (IEC Standard Voltages) and is included in several British Standards such as BS 6622 (Electric cables – Armoured with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV – Requirements and test methods.), BS 7835 (Electric cables – Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire – Requirements and test methods)as well as Part 4.10 of BS 7870 (Specification for distribution cables with extruded insulation of rated voltages of 11kV to 33kV – single-core 11kV to 33kV cables).