CONSTRUCTION

  • Conductor: tinned copper wire stranded circular class 2
  • Conductor screen: black semiconductive layer
  • Insulation: compound type EPR
  • Insulation screen: black easy strippable semiconductive layer
  • Screen: plain copper tape
  • Filler: if necessary Inner covering: elastomeric compound LSZH
  • Armour: Galvanized steel braid wire (GSWB)*
  • Outer sheath: elastomeric compound SHF2 (MUD resistant)
  • Standard colour: red
  • Marking: ELECTRIC CABLE 6000/10000 V + TRATOS Cable type (e.g. A SHF2) Cable Size(e.g. “1×150”) COMMODITY CODE IEC 60092-354 IEC 60332-3-22 Cat. A+ lot production + year + metre marking

Standards

Technical Specifications

  • IEC 60092 -354 Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) IEC 60092-352 Choice and installation of electric cables
  • IEC 60092-503 Special features – AC supply systems with voltages in the range of above 1 kV up to and including 15 kV
  • IEC 60228 conductors of insulated cables
  • IEC 60092- 360 Insulating and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunication cables
  • IEC 60332-1-2 Test for vertical flame propagation for single insulated wire or cable
  • IEC 60332-3-22 Test for the vertical flame spread of vertically-mounted bunched wires or cables – Category A
  • IEC 60754 test on gases evolved during combustion of electric cables
  • IEC 61034 measurement of smoke density of cables burning under defined conditions
  • IEC 61892-4 MUD resistance

Contact us

Please, don’t hesitate to contact us for additional information on our company or our products.

Related Case Studies

Other News

Our website uses cookies and thereby collects information about your visit to improve our website (by analyzing), show you Social Media content and relevant advertisements. Please see our cookies page for further details or agree by clicking the 'Accept' button.

Cookie settings

Below you can choose which kind of cookies you allow on this website. Click on the "Save cookie settings" button to apply your choice.

FunctionalOur website uses functional cookies. These cookies are necessary to let our website work.

AnalyticalOur website uses analytical cookies to make it possible to analyze our website and optimize for the purpose of a.o. the usability.

Social mediaOur website places social media cookies to show you 3rd party content like YouTube and FaceBook. These cookies may track your personal data.

AdvertisingOur website places advertising cookies to show you 3rd party advertisements based on your interests. These cookies may track your personal data.

OtherOur website places 3rd party cookies from other 3rd party services which aren't Analytical, Social media or Advertising.