TRATOS® RFOU(i) S1/S5

INSTRUMENTATION CABLES 250 V ACCORDING TO NEK606

Special Cables / Oil & Gas Cables / Oil & Gas NEK TS 606

CU/EPR/ZERO HAL/TCWB/EVA – Halogen Free & MUD Resistant – Individual screen

 

STANDARDS

  • Design and construction: IEC 60092-353
  • Nominal Voltage: 250 V
  • Operating temperature: 90°C
  • Flame Retardancy: IEC 60332-1 IEC 60332-3-22
  • Corrosivity: IEC 60754-1; IEC 60754-2
  • Smoke Density: IEC 61034-2
  • MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D
  • CSA C22 .2 No 38-95 Cold bend and Impact test (-40oC) (on request)

 

 

CONSTRUCTION

  • Conductor: stranded tinned copper IEC 60228 Class 2
  • Insulation: halogen free EPR compound
  • Pairs/triples: numbered and individually screened by copper/polyester tape + stranded tinned copper drain wire
  • Bedding: halogen free compound
  • Armour: tinned copper wire braid according to IEC 60092-376:2003
  • Outer sheath: SHF2 thermoset compound halogen free & MUD resistant
  • Sheath colour: grey (blue for intrinsically safe)

Standards

Technical Specifications

  • Design and construction: IEC 60092-353
  • Nominal Voltage: 250 V
  • Operating temperature: 90°C
  • Flame Retardancy: IEC 60332-1 IEC 60332-3-22
  • Corrosivity: IEC 60754-1; IEC 60754-2
  • Smoke Density: IEC 61034-2
  • MUD Resistance: NEK 606:2009; IEC 61892-4 Annex D
  • CSA C22 .2 No 38-95 Cold bend and Impact test (-40oC) (on request)

Contact us

Please, don’t hesitate to contact us for additional information on our company or our products.

Related Case Studies