DefenceMOD®

Tratos manufactures and supplies defence and marine cable for marinas, submarines, aerospace and defence internationally.

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Miniature Multi Core Silicone Insulated Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Multi Core Collectively Screened Silicone Insulated Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

 

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Multi Pair Individually Screened Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

SCREEN

Tinned copper wire braid screen applied over each individual pair

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Multi Core Individually Screened Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

SCREEN

Tinned copper wire braid screen applied over each individual core

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Single and Multipair Core Silicone Insulated Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-527®

Defence Standard 02-527 Issue 1 (previously NES527)

Single Core Silicone Insulated Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Fire resistant cable for power, control, lighting use in Her Majesty’s military vessels where the cable is required to retain circuit integrity in the event of a fire, for emergency lighting, alarms and shutdown systems.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.

Construction

Stranded tinned annealed copper wires Class 2 conductors according to BS EN 60228

INSULATION

Extruded silicone rubber insulation + fibreglass braid and lacquer

Cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-527 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Meets 3 hour 750°C fire test (identical to IEC60331)
BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 105°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Collectively Screened Flexible Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore cables having flexible conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Bunched or multiple stranded tinned annealed copper wires

Class 5 conductors according to BS EN 60228

INSULATION

Black special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification: 2 core – blue, brown 3 core – green/yellow, blue, brown 4 core – green/yellow, black, blue, brown 5 core – green/yellow, black, blue, brown, black 7 core – cores shall be number printed

SCREEN

Collective tinned copper wire braid screen

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Collectively Screened Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore cables having stranded conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Stranded tinned annealed copper wires
Class 5 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Individually Screened Flexible Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore cables having flexible conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Bunched or multiple stranded tinned annealed copper wires

Class 5 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

SCREEN

Composite tinned copper – nylon braid applied over each individual core

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE 

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Collectively Screened Flexing Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore cables having flexible conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Bunched or multiple stranded tinned annealed copper wires

Class 5 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE 

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Degaussing Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore cables having stranded conductors for degaussing control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Stranded tinned annealed copper wires
Class 2 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

 

* If optional binder tape is used over laid up cores, diameter is increased by 0 .3mm.

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Special Tratos JBA® Flexible Limited Fire Hazard (LFH).
Insulated and Sheathed Cable for Military Vessels.
Multicore cables having flexible conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels .
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire .
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present .

Construction

Bunched or multiple stranded tinned annealed copper wires

Class 5 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

 

* If optional binder tape is used over laid up cores, diameter is increased by 0 .3mm.

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Single Core Special Tratos JBA® Flexible Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Single core cables having flexible conductors for power, lighting, control circuits in Her Majesty’s surface ships and vessels.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Bunched or multiple stranded tinned annealed copper wires

Class 5 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Multi Core Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multi-core cables for power, lighting, control circuits in Her Majesty’s surface ships and vessels .
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire .
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present .

Construction

Stranded tinned annealed copper wires
Class 2 conductors according to BS EN 60228

INSULATION

Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

Core Identification, cores shall be number printed

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 02-526®

Defence Standard 02-526 Issue 2 Amendment 1 (prev. NES526)

Single Core Special Tratos JBA® Limited Fire Hazard (LFH) Insulated and Sheathed Cable for Military Vessels
Single-core cables for power, lighting, control circuits in Her Majesty’s surface ships and vessels .
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire .
For use in fixed applications and suitable for use where fuel, lubricating oils, hydraulic fluids and water are present .

Construction

Stranded tinned annealed copper wires
Class 2 conductors according to BS EN 60228

INSULATION

• Special Tratos Defence JBA® Dual layer LFH elastomeric compound according to Defence Standard 02-526

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 02-526 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to BS EN 60332-1-2 for completed cables with individual conductor size less than 4 .0mm2

BS EN 60332-3-23 NMV 3 .5 (IEC60332-3-23 Category B) as a minimum, for completed cables with individual conductor sizes 4 .0mm2 and greater

In addition, the outer sheath also displays the following characteristics:

Minimum oxygen index: 30%

Minimum temperature index: 250°C

WORKING SPECIFICATIONS

Voltage Rating: 440 volts (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating 90°C maximum conductor operating temperature
Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

TRATOS-MOD 61-12® 5IR

Defence Standard 61-12 Part 25 Issue 5 (previously NES525)

Collectively Screened Multi Triple Special Tratos JBA® Limited Fire Hazard (LFH) Insulated and Sheathed Cable for Military Vessels
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire
Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present

Construction

Stranded tinned annealed copper wires
Class 5 conductors according to Def Stan 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641 • Minimum oxygen index: 30%
Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d .c . (between cores, or between cores and ships structure, or between cores and cable screen) •

Temperature Rating: 85°C maximum conductor operating temperature .

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter .

TRATOS-MOD 61-12® 5IO

Defence Standard 61-12 Part 25 Issue 5 (previously NES525) Individually and Collectively

Screened Multi Pair Special Tratos JBA® Limited Fire Hazard (LFH)
Insulated and Sheathed Cable for Military Vessels
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Stranded tinned annealed copper wires
Class 5 conductors according to Def Stan 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

SCREEN

Collective tinned copper wire braid screen and tinned copper wire braid screen applied over each individual pair

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641 • Minimum oxygen index: 30%
Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d .c . (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 85°C maximum conductor operating temperature .

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter .

TRATOS-MOD 61-12® 5

Defence Standard 61-12 Part 25 Issue 5 (previously NES525)

Individually Screened Multi Pair Special Tratos JBA® Limited Fire Hazard (LFH) Insulated and Sheathed Cable for Military Vessels
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire • Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Stranded tinned annealed copper wires Class 5 conductors according to 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

SCREEN

Tinned copper wire braid screen applied over each individual pair

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641 • Minimum oxygen index: 30%
Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d .c . (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 85°C maximum conductor operating temperature .

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter .

TRATOS-MOD 61-12® 4

Defence Standard 61-12 Part 25 Issue 5 (previously NES525)

Collectively Screened Multi Pair Special Tratos JBA® Limited Fire Hazard (LFH) Insulated and Sheathed Cable for Military Vessels.
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present

Construction

Stranded tinned annealed copper wires
Class 5 conductors according to Def Stan 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641 • Minimum oxygen index: 30%
Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d .c . (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 85°C maximum conductor operating temperature .

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter .

TRATOS-MOD 61-12® 2I

Defence Standard 61-12 Part 25 Issue 5 (previously NES525)

Collectively Screened Multi Core Special Tratos JBA® Limited Fire Hazard (LFH) Insulated and Sheathed Cable for Military Vessels.
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines.
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire.
Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present.

Construction

Stranded tinned annealed copper wires
Class 5 conductors according to Def Stan 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

SCREEN

Collective tinned copper wire braid screen

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641 • Minimum oxygen index: 30%
Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d .c . (between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 85°C maximum conductor operating temperature .

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter .

TRATOS-MOD 61-12® 1A

Defence Standard 61-12 Part 25 Issue 5 (previously NES525)

Multi-Core Limited Special Tratos JBA® Limited Fire Hazard (LFH)Insulated and Sheathed Cable for Military Vessels
Multicore lightweight thin-wall insulated cables for power, lighting, control, communication and instrumentation circuits in Her Majesty’s surface ships and submarines
Incorporates Limited Fire Hazard (LFH) insulation and sheath for reduced levels of smoke and toxic fumes in the event of a fire
Suitable for use in fixed or flexible applications where fuel, lubricating oils, hydraulic fluids and water are present

Construction

Stranded tinned annealed copper wires

Class 5 conductors according to Def Stan 61-12 Part 18

INSULATION

Thin wall LFH Tratos Defence Insulation to Defence Standard 61-12 part 25

OUTER SHEATH

Special Tratos Defence JBA® Black LFH elastomeric compound according to Defence Standard 61-12 part 31

Cable sheath marking + Tratos + year of manufacture + Def Stan 61-12 part 25 + Last seven digits of the NSN number

TECHNICAL SPECIFICATIONS

FIRE PERFORMANCE

Flame retardant to Defence Standard 02-641

Minimum oxygen index: 30%

Minimum temperature index: 250 °C

WORKING SPECIFICATIONS

Voltage Rating: 600 Vrms/800 V d.c.(between cores, or between cores and ships structure, or between cores and cable screen)

Temperature Rating: 85°C maximum conductor operating temperature.

Note: Cables also retain a degree of flexibility under weather deck conditions of -30°C

Minimum cable bending radius: Flexing applications 10 x overall cable diameter, fixed applications 4 x overall cable diameter.